The edge demand driven by AI computing is now translating into the power supply and voltage regulation segments of the analog chain becoming the core engine for industry recovery From a product line perspective TIs data center related portfolio covers the entire power delivery path from the AC grid to the GPU core with a core strategy centered on end to end power and signal solutions anchored by power management.
1. Product Line Overview: Four Major Segments
|
Category
|
Application Positioning
|
Representative Products
|
|---|---|---|
|
Power Management
|
The core module of data centers, covering the full-link power supply from AC/DC to the CPU/GPU core.
|
Multiphase controllers, power stages, point-of-load regulators, hot-swap controllers.
|
|
Signal Chain
|
Signal integrity and high-speed data transmission.
|
Clock and timers, data converters (ADC/DAC), signal conditioners, amplifiers.
|
|
Interface & Connectivity
|
Internal and external data transmission links for servers.
|
PCIe/SAS/SATA redrivers/retimers, SerDes, USB controllers.
|
|
Embedded Processing
|
The control core for power management and system monitoring.
|
Real-time digital power MCUs, edge AI acceleration MCUs.
|
Power management plays a leading role, covering the complete chain from AC power input to supplying processors, GPUs, and AI accelerators. The data center power architecture can be divided into four tiers:
|
Tier
|
Product Category
|
Main Function
|
Key Products / Technologies
|
|---|---|---|---|
|
AC/DC Conversion
|
High-voltage GaN power stages, digital controllers, isolated gate drivers
|
Convert grid AC power to high-voltage DC power
|
30kW 800V AC/DC reference design
|
|
Rack-level DC Distribution & Protection
|
Hot-swap controllers, integrated electronic fuses (eFuse), high-voltage GaN power stages
|
800V/48V rack power supply protection and distribution
|
TPS1689 / TPS1685 48V hot-swap eFuse
|
|
Intermediate Bus Conversion
|
Isolated bus converters, Gallium Nitride (GaN) modules
|
48V/12V → 6V intermediate voltage conversion
|
LMM104RM0 GaN module, size of only a quarter-brick
|
|
Processor Core Power Supply
|
Multiphase controllers, smart power stages, point-of-load (PoL) regulators
|
6V → ≤1V for CPU/GPU/ASIC power supply
|
CSD965203B dual-phase smart power stage
|
USB Hubs and Controllers: Support USB Type-C and Power Delivery (PD) standards, used for standardized connectivity of data center management interfaces
MCUs and processors serve as the brain of the data center power management system. TI has specifically developed a real-time MCU product line for high-density, ultra-low-latency digital power control, ensuring the power loop feedback time is sufficiently short to adapt to rapidly changing CPU/GPU loads.
|
Series
|
Core Architecture
|
Data Center Applications
|
|---|---|---|
|
C2000 Series
|
32-bit C28 core
|
Digital power control, Power Factor Correction (PFC)
|
|
F29H85
|
Triple-core 200MHz 64-bit C29
|
High-end, high-reliability control for industrial and data center needs
|
|
Sitara AM2x/AM6x
|
Arm Cortex-R5F + Cortex-A53
|
Power management and data center power monitoring, combining real-time control and connectivity
|
|
AM263P
|
Quad-core 400MHz Arm
|
Battery Management Systems (BMS) and liquid-cooling distribution network control
|