Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
AMI-B11AW1-13-6-BLINE FILTER 250VAC 6A TH |
1,285 | 11.81 |
|
![]() Datasheet |
AMI-B11AW | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Through Hole | PC Pins | 1.89mH |
![]() |
AMI-M11A-1-1-BLINE FILTER 250VAC 1A CHASS MNT |
3,020 | 11.85 |
|
![]() Datasheet |
AMI-M11A | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 1 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.86mH |
![]() |
FN610A-10-06LINE FILTER 250VAC 10A CHASS MNT |
2,247 | 0.00 |
|
![]() Datasheet |
FN 610 | Tray | Obsolete | Single Phase | Single Stage | - | 250V | - | - | 10 A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 450µH |
![]() |
AMI-M11R-7M-3-B-2LINE FILTER 250VAC 3A CHASS MNT |
1,177 | 10.11 |
|
![]() Datasheet |
AMI-M11R | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 7.06mH |
![]() |
AGM-10LINE FILTER 250VAC 10A CHASS MNT |
2,142 | 14.33 |
|
![]() Datasheet |
AGM | Box | Obsolete | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | Medical | CE, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
![]() |
EMC-20LINE FILTER 85V-305VAC 1.5A TH |
1,062 | 13.25 |
|
![]() Datasheet |
EMC-20 | Tray | Not For New Designs | Single Phase | Single Stage | - | 85V ~ 305V | - | - | 1.5 A | 47Hz, 63Hz | General Purpose | - | -40°C ~ 85°C | Through Hole | PC Pins | - |
![]() |
AMI-23B-10-1LINE FILTER 250VAC 10A CHASS MNT |
2,179 | 12.47 |
|
![]() Datasheet |
AMI-23 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | - |
![]() |
AG-016LINE FILTER 110V/250VAC 16A CHAS |
3,469 | 13.73 |
|
![]() Datasheet |
AG | Box | Obsolete | Single Phase | Single Stage | - | 110V, 250V | - | - | 16 A | 50/60Hz | General Purpose | cCSAus, CE, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
![]() |
AMI-M12T-1-6-BLINE FILTER 250VAC 6A CHASS MNT |
1,811 | 10.27 |
|
![]() Datasheet |
AMI-M12T | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.8mH |
![]() |
AMI-29A-1-3LINE FILTER 250VAC 1A CHASS MNT |
1,647 | 11.67 |
|
- |
AMI-29 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 40mH |
![]() |
AMI-29B-1-3LINE FILTER 250VAC 1A CHASS MNT |
1,803 | 11.67 |
|
- |
AMI-29 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 40mH |
![]() |
AMI-29A-3-1LINE FILTER 250VAC 3A CHASS MNT |
3,073 | 11.67 |
|
- |
AMI-29 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 3 A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 28mH |
![]() |
FMAB-N6PG-0146LINE FLTR 277/400VDC 277VAC CHAS |
4,955 | 13.64 |
|
![]() Datasheet |
FMAB | Box | Active | Single Phase | Single Stage | 277V, 400V | 277V | - | - | 1 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
![]() |
AMI-23-8-3LINE FILTER 250VAC 8A CHASS MNT |
2,560 | 11.69 |
|
![]() Datasheet |
AMI-23 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 8 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 8mH |
|
5003.1131.1LINE FILTER 125VDC 3A PANEL MNT |
2,447 | 11.06 |
|
![]() Datasheet |
5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | 3 A | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | Quick Connect | 4mH |
![]() |
AMI-M11J-1-20-B-1LINE FILTER 250VAC 20A CHASS MNT |
4,935 | 11.16 |
|
![]() Datasheet |
AMI-M11J | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 440µH |
![]() |
AMI-M11H-1-10-ALINE FILTER 250VAC 10A CHASS MNT |
3,995 | 11.16 |
|
![]() Datasheet |
AMI-M11H | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | Medical | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 465µH |
![]() |
AMI-M12Q-1-6-BLINE FILTER 250VAC 6A CHASS MNT |
4,171 | 11.16 |
|
![]() Datasheet |
AMI-M12Q | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | 50/60Hz | Medical | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.83mH |
![]() |
AMI-23A-8-3LINE FILTER 250VAC 8A CHASS MNT |
3,871 | 11.89 |
|
![]() Datasheet |
AMI-23 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 8 A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 8mH |
![]() |
AMI-23B-8-3LINE FILTER 250VAC 8A CHASS MNT |
1,843 | 11.89 |
|
![]() Datasheet |
AMI-23 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 8 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 8mH |