Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature | Voltage - Supply | Current - Supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
QTS-61120X-E000000SENSOR CHLORINE -20-50DEGC OUT Automation Components, Inc. |
4,887 | 0.00 |
|
- |
- | Tape & Box (TB) | Active | Chlorine (CL2) | - | ±2.5% | 4mA ~ 20mA | -20°C ~ 50°C | 12V ~ 36V | 25mA |
![]() |
QTS-17191X-S000000-ACETONESENSOR -40DEGC-50DEGC OUTPUT Automation Components, Inc. |
4,977 | 0.00 |
|
![]() Datasheet |
- | Tape & Box (TB) | Active | - | - | - | 4mA ~ 20mA | -40°C ~ 50°C | 12V ~ 30V | 125mA |
![]() |
Q5-CO2-5V-O-XSENSOR CARB DIOX -20-50DEGC OUT Automation Components, Inc. |
1,226 | 0.00 |
|
- |
- | Tape & Box (TB) | Active | Carbon Dioxide (CO2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
![]() |
Q5-CO2-5000P-O-XSENSOR CARB DIOX -20-50DEGC OUT Automation Components, Inc. |
2,196 | 0.00 |
|
- |
- | Tape & Box (TB) | Active | Carbon Dioxide (CO2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
![]() |
Q5-CO2-100V-O-XSENSOR CARB DIOX -20-50DEGC OUT Automation Components, Inc. |
2,304 | 0.00 |
|
- |
- | Tape & Box (TB) | Active | Carbon Dioxide (CO2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
![]() |
Q5-CO2-20V-O-XSENSOR CARB DIOX -20-50DEGC OUT Automation Components, Inc. |
3,934 | 0.00 |
|
- |
- | Tape & Box (TB) | Active | Carbon Dioxide (CO2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
![]() |
B5-CO2-5000P-O-XSENSOR CARB DIOX -20-50DEGC OUT Automation Components, Inc. |
3,755 | 0.00 |
|
![]() Datasheet |
- | Tape & Box (TB) | Active | Carbon Dioxide (CO2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
![]() |
B5-CO2-5V-O-XSENSOR CARB DIOX -20-50DEGC OUT Automation Components, Inc. |
1,977 | 0.00 |
|
![]() Datasheet |
- | Tape & Box (TB) | Active | Carbon Dioxide (CO2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
![]() |
Q5-NH3-100P-O-XSENSOR AMMONIA -30-50DEGC OUTPUT Automation Components, Inc. |
1,617 | 0.00 |
|
- |
- | Tape & Box (TB) | Active | Ammonia (NH3) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -30°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
![]() |
Q5-NH3-1000P-O-XSENSOR AMMONIA -30-50DEGC OUTPUT Automation Components, Inc. |
1,157 | 0.00 |
|
- |
- | Tape & Box (TB) | Active | Ammonia (NH3) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -30°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |